IQ Rooftop packaged unit

IQ Rooftop packaged unit

Categories , ,
5/5

Features

  1. 1. Various products and wide application
    The series of Rooftop units include many different specifications which can completely meet the demand of home and
    commercial places and offer you a comfortable and pleasant environment.
    2. Complete air system, simple and hygiene, less components, easy maintenance
    The flexible and concise design makes the maintenance very simple. Disassembling several bolts from any side of the unit
    can repair any part of the unit.
    3. Microcomputer intelligent controller can reach four control modes: cooling, dehumidifying, and ventilation. It also has
    the functions of timing on-off and failure display.
    4. Excellent performance
    World well-known brand of main parts are used. To guarantee the rational match of the unit, strict performance testing
    is done. Besides the unit runs steady and the vibration and noise are effectively controlled by the use of multi-vane pitch
    centrifugal fan, world-known high efficiency compressor and the elaborative-designed controller, motor, etc.
    5. Quiet operation and Convenient maintenance
    Reach the lowest noise of the a/c room. The a/c units are placed far from the a/c area which meets the demand of indoor
    low noise to the greatest degree. The adoption of high efficiency and low noise centrifugal fan makes the quiet operation
    come true

 

Free cooling logic:

  1. When it is cooling:
    a. When indoor room temperature (temperature set) – outdoor temperature ≥ 4 ℃,fresh air damper is 100% open,
    and return air damper is 100% closed,only the evaporator fan is running to blow air into room;
    b. When 0 ℃ ≤ indoor room temperature (temperature set) – outdoor temperature< 4 ℃ ,both fresh air damper
    and return air damper are closed, and the unit is not running;
    c. When indoor room temperature ( temperature set) – outdoor temperature < 0℃,the return air damper is 100%
    open,and fresh air damper is 100% closed,then the compressor, condensing fan and evaporator fan will work normally
    to blow cool air into room.
  2. When it is heating:
    It operate in similar way as for free cooling.

Optional heat recovery

Available with a hygroscopic or non-hygroscopic rotor for recovering and transferring
heat energy from the exhaust to the supply air streams.

Optional filter

G3 aluminium filter is standard, optional preliminary, medium filter are
optional.

Optional supply air outlet and return air inlet at the unit bottom

It is optional to have the supply air outlet and return air inlet at
bottom.

Optional MEPS efficiency

It is optional to have the units with efficiency as per MEPS standard.

Dimension

IQRTU72, 96, 125

NOTES:
1. Unit installation hole 4xΦ12.5;
2. Unit lifting hole 4xΦ35;
3. Control box ;
4. Power supply cable inlet hole Φ22;
5. Communication cable inlet hole Φ16;
6. Drain water pipe diameter 1″.

IQRTU168, 180

NOTES:
1. Unit installation hole 4xΦ12.5;
2. Unit lifting hole 4xΦ35;
3. Control box ;
4. Power supply cable inlet hole Φ22;
5. Communication cable inlet hole Φ16;
6. Drain water pipe diameter 1″.

IQRTU210, 250

NOTES:
1. Unit installation hole 4xΦ12.5;
2. Unit lifting hole 4xΦ45;
3. Control box ;
4. Power supply cable inlet hole Φ35;
5. Communication cable inlet hole Φ22;
6. Drain water pipe diameter 1″.

IQRTU300, 360

NOTES:
1. Unit lifting hole 4xΦ50;
21. Unit installation hole 4xΦ12.5;
3. Power supply cable inlet hole Φ45;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1″.

IQRTU415, 480, 520

NOTES:
1. Unit lifting hole 4xΦ50;
21. Unit installation hole 4xΦ12.5;
3. Power supply cable inlet hole Φ35;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1″.

IQRTU630,750

NOTES:
1. Unit lifting hole 4xΦ50;
2. Unit installation hole 4xΦ12.5;
3. Power supply cable inlet hole Φ50;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1″.

IQRTU1023

NOTES:
1. Unit lifting hole 4xΦ50;
2. Unit installation hole 8xΦ12.5;
3. Power supply cable inlet hole Φ80;
4. Communication cable inlet hole Φ16;
5. Control box ;
6. Drain water pipe diameter 1″.